EMI, Shock and Vibration Certifications
|
Compliance Directives |
Standards ID |
Overview |
|---|---|---|
|
CE |
IEC 61000-4-2: 2008 |
Electrostatic discharge immunity |
|
IEC 61000-4-3: 2020 |
Radiated radio-frequency electromagnetic field immunity |
|
|
IEC 61000-4-4: 2012 |
Electrical fast transient immunity |
|
|
IEC 61000-4-5: 2014 A1: 2017 |
Surge immunity |
|
|
IEC 61000-4-6: 2013 |
Immunity to conducted disturbances |
|
|
IEC 61000-4-8: 2009 |
Magnetic field immunity |
|
|
IEC 61000-4-11: 2020 |
Voltage dips, short interruptions and voltage variation immunity |
|
|
CISPR 11: 2015 A1: 2016 A2: 2019 |
Radiated emission measurements (30 MHz—1 GHz) ; |
|
|
CISPR 32: 2015 A1: 2019 (Class A) |
Radiated emission measurements (30 MHz—6 GHz); Conducted emission measurements on wired network port; |
|
|
FCC & ICES |
CFR 47 FCC, Part 15, Subpart B: 2021; |
Radiated emission measurements (30 MHz—40 GHz); |
|
KC |
Clause 3, Article 58-2 of Radio Waves Act |
|
|
RoHS |
Compliancy as per European directive 2014/30/EU (EMC) and directive 2011/65/EU as amended by EU 2015/863 (RoHS2) |
|
|
Vibration & Shock Tests |
Test Levels (while operating) |
Test Parameters |
|
Random vibrations |
Level 1: 2 grms 60 min |
Frequency range: 5 to 2000 Hz |
|
Shocks |
Level 1: 20 g / 11 ms |
Shape: half-sine |
|