Description

Selects which internal signal or event driven pulse or software control state to output on the selected output line.

DETAIL VALUE

Feature name

outputLineSource

Type

IEnumeration

Access Mode

Read and Write *

Specification

DALSA

Visibility

Beginner

* Access Mode and/or Range values depend on other features.

Options

Display Option Description

Off

Off

Line output is Open

SoftwareControlled

Software Controlled

The OutputLineValue feature changes the state of the output.

PulseOnStartofFrame

Pulse on: Start of Frame

Generate a pulse on the start of the Frame Active event.

PulseOnStartofExposure

Pulse on: Start of Exposure

Generate a pulse on the ExposureStart event. This option is typically used to trigger a strobe light.

PulseOnEndofExposure

Pulse on: End of Exposure

Generate a pulse on the ExposureEnd event. This option is typically used to trigger a strobe light.

PulseOnStartofReadout

Pulse on: Start of Readout

Generate a pulse on the ReadoutStart event.

PulseOnEndofReadout

Pulse on: End of Readout

Generate a pulse on the ReadoutEnd event.

PulseOnValidFrameTrigger

Pulse on: Valid Frame Trigger

Generate a pulse on the FrameTrigger event.

PulseOnInvalidFrameTrigger

Pulse on: Rejected Frame(s) Trigger

Generate a pulse on the Invalid FrameTrigger event.

PulseOnStartofAcquisition

Pulse on: Start of Acquisition

Generate a pulse when the AcquisiontStart event occurs.

PulseOnEndofAcquisition

Pulse on: End of Acquisition

Generate a pulse when the AcquisiontStop event occurs.

PulseOnEndofTimer1

Pulse on: End of Timer 1

Generate a pulse on the TimerEnd 1 event.

PulseOnEndofCounter1

Pulse on: End of Counter 1

Generate a pulse on the CounterEnd 1 event.

PulseOnInput1

Pulse on: Input 1 Event

Generate a pulse on the Input signal 1 event.

PulseOnInput2

Pulse on: Input 2 Event

Generate a pulse on the Input signal 2 event.

PulseOnAction1

Pulse on: Action 1

Generate a pulse on the GigEVision Action Command 1.

PulseOnAction2

Pulse on: Action 2

Generate a pulse on the GigEVision Action Command 2.

PulseOnSoftwareCmd

Pulse on: Software Command

Generate a pulse on the Input of a Software Command

ExposureActive

Exposure Active

Generate a signal that is active when the Exposure is active.