Output Line Software Command
Description
Writing a value of 1 in the bit field applies the Latch value of the outputLineSoftwareLatchControl and/or executes the PulseOnSoftwareCmd for any output line programmed for software control. The feature outputLineSoftwareCmd can take any binary value and each bit set to 1 corresponds to a Icommand for an Output. Note that Outputs are numbered from 1 to N, therefore Bit 1 of outputLineSoftwareCmd corresponds to Output1. This is applicable to OutputLineSource = Pulse On: where Software Cmd (for Pulse mode) or OutputLineSource = SoftwareControlled and OutputLineSoftwareLatchControl = Latch (for static states).
| DETAIL | VALUE |
|---|---|
|
Feature name |
outputLineSoftwareCmd |
|
Type |
IInteger |
|
Access Mode |
Read and Write |
|
Range (increment) |
0 – 4294967295 (incr. 1) |
|
Specification |
DALSA |
|
Visibility |
Expert |
©