Description

Specifies the internal signal or physical input line to use as the timestamp reset source.

DETAIL VALUE

Feature name

timestampResetSource

Type

IEnumeration

Access Mode

Read and Write *

Specification

DALSA

Visibility

Expert

* Access Mode and/or Range values depend on other features.

Options

Display Option Description

None

None

No timestamp reset source is specified. Note that the Timestamp reset command can still reset the counter.

Line1

Line 1

Use input line 1 as the timestamp reset source.

Line2

Line 2

Use input line 2 as the timestamp reset source.

Action2

Action 2

Select the GigEVision Action Command 2 as the timestamp reset source. This is a broadcast command that multiple devices can respond to simultaneously.