Description

Selects the signal source to reset the counter. After a reset the counter waits for the next countStartSource signal or event.

DETAIL VALUE

Feature name

counterResetSource

Type

IEnumeration

Access Mode

Read and Write *

Specification

DALSA

Visibility

Expert

* Access Mode and/or Range values depend on other features.

Options

Display Option Description

Off

Reset Cmd

Reset on reception of the Reset Icommand.

AcquisitionStart

Acquisition Start

Reset on reception of the Acquisition Start.

AcquisitionEnd

Acquisition End

Reset on reception of the Acquisition End.

ExposureStart

Exposure Start

Reset on reception of the Exposure Start event.

ExposureEnd

Exposure End

Reset on reception of the Exposure End event.

ReadoutStart

Readout Start

Reset the counter on the reception of the Readout Start event.

ReadoutEnd

Readout End

Reset the counter on the reception of the Readout End event.

FrameStart

Frame Trigger

Reset on reception of the Frame Trigger.

ValidFrameTrigger

Valid Frame Trigger

Reset on reception of the Valid Frame Trigger

InvalidFrameTrigger

Rejected Frame Trigger

Reset on reception of the Invalid Frame Trigger

FrameBurstEnd

MultiFrame End Trigger

Reset on reception of the Frame Burst end.

Line1

Line 1

Reset the Counter on the specified transitions on Line 1.

Line2

Line 2

Reset the Counter on the specified transitions on Line 2.

Timer1End

Timer 1 End

Reset on reception of the Timer 1 End.

Counter1End

Counter 1 End

Reset on the reception of the Counter end.